Containment Solutions Inc. CSI is the largest American fiberglass tank, manufacturer. CSI instituted and perfected the use of specially treated silica in their laminate matrix. The CSI tank wall is composed of resin, glass and specially treated silica that together results in a composite matrix compatible with petroleum industry products including:. Highland Tanks combine the structural strength of steel with the lasting protection of polyurethane.
All underground tanks are coated in polyurethane, which provides permanent and effective corrosion protection for the life of the tank. If corrosion is your biggest concern then the P3 line of tanks offers protection in three ways: dielectric coating, electrical isolation, and sacrificial anodes. Theses tanks are offered in both commercial and residential models. In addition to fuel and lube oil storage tanks, models are also available for potable water storage, fire suppression, and wastewater.
The tanks come with a 20 to year guarantee, depending on the model, when installed to the manufacturer's specifications by a certified tank installer. With so many factors to consider and so many precautions to take, you need to know that the team you call on has the experience and expertise to perform the job and follow all of the requirements of the Maryland Dept.
Our expert equipment operators have removed many tanks that other companies said is not possible. We will provide you a complete job to include everything you need:. However it is more expensive to abandon the tank in place instead of removing it. If the tank is leaking, it has to be removed anyway. We can inspect the property and write a report of our findings. We will be able to come and check the underground tank and we can determine the size of the tank, the orientation and how long it is where the ends of the tank are.
We can determine if the tank is under an Air Conditioner unit or sidewalk. We can determine how much liquid product is in the tank and if there is any water in the tank which could possibly indicate a leak. Having trouble finding your tank? Is the tank Fill pipe and or vent pipe Missing? Our team of highly trained professionals will locate it for you. We can also take the time to find the perfect spot to place your new tank whether that be aboveground or underground.
Has your oil company told you they will no longer fill the tank due to a Non-functioning whistle vent? Depending on the age of your underground tank a tank test may be a good option for you, however if your tank is over 20 years old we do not recommend a tank test. Call us for more information. If you need to have the tank checked, we would recommend a soil sample. We can perform a soil sample and auger down next to the tank and check the soil below the tank.
Similarly, for cold-weather applications, fuel heaters are required to maintain fuel viscosity and prevent injector plugging due to wax formation. The fuel flash point is the lowest temperature at which the fuel will ignite in the presence of an ignition source.
NFPA 30 defines combustible liquids as having a flash point equal to or greater than F The flash point of conventional diesel fuel typically ranges between F and F Therefore, diesel fuel is considered a combustible liquid. However, it is important to note that when diesel fuel is blended with ethanol E-diesel to reduce emissions, the blended diesel fuel has a low flash point of about 68F 20C.
The blended fuel is therefore considered a flammable liquid, requiring management of associated fire and explosion hazards. For simplicity, this article considers only conventional diesel fuel.
Biodiesel can be used alone or blended with petroleum diesel. Sizing the Bulk Diesel Storage Tank. The size of a bulk diesel storage tank can depend on a number of factors, including the classification of the emergency power supply system EPSS in some applications. Bulk Diesel Storage Tank Installation. Bulk tanks can be installed above ground, within a storage tank vault, underground direct buried , or within a storage tank building.
Above-ground tanks Figure 2 must be provided with emergency relief venting that will release internal pressure, if the tank is exposed to fire. Means for spill control shall also be provided for above-ground tanks.
An above-ground, secondary containment-type, double-wall tank for spill control is shown here located away from property lines. Courtesy: Pxfuel. Backfill is not permitted around the tank in a vault and sufficient clearance is required around the tank for inspection and maintenance purposes.
Underground tanks and piping require external corrosion protection by means of cathodic protection or use of corrosion-resistant material. The base and fill shall be clean, non-corrosive, compacted sand or compacted gravel. Storage tank buildings are subject to minimum separation distances from property lines, public ways, and important buildings on the same property. Such tanks are permitted to operate from atmospheric pressure to a gauge pressure of 1. Other design standards may be used but the pressure limits should be checked to avoid distortion of the tank shell during service.
Venting of Bulk Diesel Storage Tanks. Bulk diesel storage tanks should be equipped with a vent line to prevent vacuum formation or overpressure in the tank during drawdown or tank filling, or due to atmospheric temperature changes. The vent pipe shall discharge to a safe space at least five feet away from building openings and at least 15 feet away from powered ventilation air intake devices.